Design and simulation an open loop AC chopper converter with an RL load with the approach of reducing the output and input total harmonic distortion

نویسندگان

  • Puya Behnia Shahrood university of technology نویسنده

DOI:

https://doi.org/%20/cka4pe88

کلمات کلیدی:

AC chopper, AC-to-AC converter, Total harmonic distortion

چکیده

In this article an open loop AC chopper is designed and simulated. The load side of the converter consists of a resistance and an inductance. The aim of this paper is to achieve both an output with low total harmonic distortion and an input with low total harmonic distortion as a result a high power factor both in the output side of the converter and in the input side of the converter will be seen; therefore the power losses during the power transmission process will be decreased but the power quality parameters in the converter will be improved. There are two main control methods for switching the power electronic switches in this converter; open loop control method and closed loop control method. In this article open loop control method is considered.

دانلودها

دسترسی به دانلود اطلاعات مقدور نیست.

بیوگرافی نویسنده

  • Puya Behnia، Shahrood university of technology

          

مراجع

[1] Rahmani, L., Krim, F., Khanniche, M. S., & Bouafia, A. (2004). Control for PWM ac chopper feeding nonlinear loads. International journal of electronics, 91(3), 149-163.‏

[2] Sundareswaran, K., & Kumar, A. P. (2004). Voltage harmonic elimination in PWM AC chopper using genetic algorithm. IEE Proceedings-Electric Power Applications, 151(1), 26-31.‏

[3] Muhs, D. et al. (2003). Roloff/Matek mechanical parts, 16th ed. Wiesbaden: Vieweg Verlag,. 791 p. (In German). ISBN 3-528-07028-5.

[4] Isik, M. F., Guvenc, U., & Yanmaz, H. (2013). AC Chopper Application and Benefits of Auxiliary Windings for PSC Motors. Elektronika ir Elektrotechnika, 19(10), 76-80.‏

[5] Nasrollahi, R., Farahani, H. F., Asadi, M., & Farhadi-Kangarlu, M. (2022). Sliding mode control of a dynamic voltage restorer based on PWM AC chopper in three-phase three-wire systems. International Journal of Electrical Power & Energy Systems, 134, 107480.‏

چاپ شده

2025-09-22

ارجاع به مقاله

Design and simulation an open loop AC chopper converter with an RL load with the approach of reducing the output and input total harmonic distortion. (2025). پایگاه مقالات مرکز همایشهای مهندسی توسعه, 2(7). https://doi.org/ /cka4pe88

مقالات مشابه

##common.pagination##

همچنین برای این مقاله می‌توانید شروع جستجوی پیشرفته مقالات مشابه.